YCB9HL-63 RCBO Electromagnetic

0 Reviews Sold: 0

1.Protection againstoverload and short-circuit currents
2.Protection against the effectsof sinusoidal alternating earth fault currents
3.Protection against indirect contacts and additional protection against directcontacts.
4.Protection against fire hazard causedbyinsulation faults
5.Usedin residentialbuilding
6.According tothe type of instantaneousrelease classified as follows:type B(3-5)In,type C(5-10)In

General

1. Protection against overload and short-circuit currents.
2. Protection against the effects of sinusoidal alternating earth fault currents.
3. Protection against indirect contacts and additional protection against direct contacts.
4. Protection against fire hazard caused by insulation faults.
5. Used in residential building.
6. According to the type of instantaneous release classified as follows: type B(3-5)ln, type C(5-10)ln.

YCB9HL-63 RCBO is an combined structure,the N pole is on the right side of the product. It has the following characteristics:
Without auxiliary power supply, it overcomes the defects of electronic products;

poor anti-interference, be greatly affected by power grid voltage fluctuation and can’t be protected if the neutral line is disconnected;
Test circuit is dynamic controlled, and the test resistance is not easy to burn;
N pole contact can be opened and closed separately, with isolation function;
The impulse withstand voltage between L pole and N pole can reach up to 6000V;
The impulse withstand voltage between L pole, N pole and the metal support can reach up to 8000V;
Under the impact current of 200A, it has the ability to bear, and does not cause misoperation.

Release

Type Test current Tripping time Expected result
B,C 1.13In t≤1h(In≤63A) Not tripping
1.13In t≤2h(In>63A
B,C 1.45In t<1h(In≤63A) Tripping
145In t<2h(In>63A)
B,C 2.55In s<t<60s(In≤32A) Tripping
2.55In 1s<t<120s(In>32A)
B 3In t≤0.1s Not tripping
C 5In t≤0.1s
B 5In t<0.1s Tripping
C 0In t<0.1s

Curve

B,C Curve

Specifications

Overall and Mounting Dimensions(mm)

Type Standard EC/EN 61009-1
Electrical features Leakage type Electromagnetic type
Rated current In A 6,10,16,20,25,32,40,50,63
ype(wave form of the earth leakage sensed) A,AC
Poles P 1P+N
Rated voltage Ue V 230
nsulation voltage Ui V 500
Rated frequenc) Hz 50/60
Rated breaking capacity Icn A 6000
Rated impulse withstand voltage (1.2/50)Uimp V 4000
Dielectric test voltage at ind.Freq.for 1min kV 2
Rated sensitivity I△n A 0.03,0.05,0.1
Break time under I△n S ≤0.1
Rated residual making and breaking capacity I△m A 500
Pollution degree 2
Mechanica features Electrical life t 4000
Mechanical life t 8000
Protection degree IP20
Storage temperature 25~+70
Ambient temperature (with daily average≤35℃) -5~+40
Installation Terminal connection type Cable/U-type bar/Pin-type busbar
Terminal size top /bottom for cable mm² 16
AWG 5月18日
Terminal size top /bottom for busbar mm² 16
AWG 5月18日
Tightening torque N*m 1.2
In-Ibs 11
Mounting On DIN rail EN 60715(35mm)by means of fast clip
Connection

color

,

Reviews

There are no reviews yet.

Be the first to review “YCB9HL-63 RCBO Electromagnetic”

Your email address will not be published. Required fields are marked *