YCB7LE-63 RCBO Electronic

0 Reviews Sold: 0

1.Protection against overload and short-circuit currents
2.Protection against the effects ofsinusoidal alternating earthfault currents
3.Protection against indirectcontacts and additional protection against direct contacts.
4.Protection against fire hazard caused by insulation faults
5.Used in residential building
6.According tothe type of instantaneous release classified as follows:type B(3-5)In,type C(5-10)In,type D(10-20)In

1. Protection against overload and short-circuit currents

2. Protection against the effects of sinusoidal alternating earth fault currents

3. Protection against indirect contacts and additional protection against direct contacts.

4. Protection against fire hazard caused by insulation faults

5. Used in residential building

6. According to the type of instantaneous release classified as follows : type B(3-5)ln, type C(5-10)ln, type D(10-20)ln

Release

Type Test current Tripping time Expected result Type Test current Tripping time Expected result
B,C,D 1.13In t≤1h(In≤63A) Not tripping B 3In t≤0.1s Not tripping
1.13In t≤2h(In>63A) C 5In t≤0.1s
B,C,D 1.45In t<1h(In≤63A) Tripping D 10In t≤0.1s
1.45In t<2h(In>63A) B 5In t<0.1s Tripping
B,C,D 2.55In 1s<t<60s(In≤32A) Tripping C 10In t<0.1s
2.55In 1s<t<120s(In>32A) D 20In t<0.1s

Curve

Specifications

Type Standard IEC/EN 61009-1
Electrical
features
Poles P 1P+N, 2, 3, 3P+N, 4
Type(wave form of the earth leakage sensed) AC
Thermo-magnetic release characteristic B, C, D
Rated current In A 6, 10, 16, 20, 25, 32, 40, 50, 63
Rated voltage Ue V 230V AC(1P+N, 2P)  400V AC(3P, 3P+N, 4P)
Rated sensitivity lΔn A 0.03, 0.05, 0.1, 0.3
Rated residual making and
breaking capacity lΔm
A 500(In≤40A) 630(In>40A)
Rated short-circuit capacity lcn A 4500
Break time under lΔn s ≤0.1
Rated frequency Hz 50/60
Rated impulse withstand voltage(1.2/50)Uimp V 4000
Dielectric test voltage at ind.Freq.for 1min kV 2
Insulation voltage Ui V 500
Pollution degree 2
Mechanical features Electrical life t 4000
Mechanical life t 10000
Contact position indicator Yes
Protection degree IP20
Ambient temperature(with daily average≤35℃) -5~+40
Installation Storage temperature -25~+70
Terminal connection type Cable/Pin-type busbar
Terminal size top/bottom for cable mm² 25
AWG 18-3
Terminal size top/bottom for busbar mm² 25
AWG 18-3
Tightening torque N*m 2
In-Ibs 18
Mounting On DIN rail EN60715(35mm)by means of fast clip device
Connection From top

Overall and mounting dimensions(mm)

color

,

Reviews

There are no reviews yet.

Be the first to review “YCB7LE-63 RCBO Electronic”

Your email address will not be published. Required fields are marked *