1.Protection against overloadand short-circuit currents
2.Protection against the effects of sinusoidalalternatingearthfault currents
3.Protection against indirect contacts andadditional protection against direct contacts.
4.Protectionagainst fire hazard causedby insulation faults
5.Usedin residential building
6.According to the type of instantaneousrelease dassified as follows:type B(3-5)In,type C(5-10)In,type D(10-20)In

General

1. Protection against overload and short-circuit currents
2. Protection against the effects of sinusoidal alternating earth fault currents
3. Protection against indirect contacts and additional protection against direct contacts
4. Protection against fire hazard caused by insulation faults
5. Used in residential building
6. According to the type of instantaneous release classified as follows : type B(3-5)ln, type C(5-10)ln, type D(10-20)ln

Release

Curve

Type lest current Tripping time Expected result lype Test current Tripping time Expected resut
B,C,D 1.13In t≤1h(In≤63A Not tripping B 3In t≤0.1s Not tripping
1.13In t≤2h(In>63A C 5In t≤0.1s
B,C,D 1.45In t<1h(In≤63A) Tripping D 10ln t≤0.1s
1.45In t<2h(In>63A) B 5In t<0.1s Tripping
B,C,D 2.55In 1s<t<60s(In≤32A) Tripping C 0In t<0.1s
2.55In 1s<t<120s(In>32A) D 20In <0.1s

Specifications

Overall and Mounting Dimensions (mm)

Type Standard EC/EN 61009-1
Electrical features Poles P 1P+N,3P+N
Type(wave form of the earth leakage sensed) A/AC
Thermo-magnetic release characteristic B,C,D
Rated current In A 1,2,3,4,6,10,16,20,25,32,40,50,63,80
Rated voltage Ue V 230/400
Rated sensitivity IAn A 0.03,0.05,0.1,0.2
Rated residual making and A 500(In≤40A)630(In>40A)
breaking capacity I△m
Rated short-circuit capacity lcn A 6000
Break time under I△n S ≤0.1
Rated frequency Hz 50/60
Rated impulse withstand voltage(1.2/50)Uimp V 4000
Dielectric test voltage at ind.Freq.for 1min kV 2
Insulation voltage Ui V 500
Pollution degree
Mechanical features Electrical life t 4000
Mechanical life t 10000
Contact position indicator Yes
Connection and nstallation Protection degree IP20
Connection capacity mm2 1~35
Circumstance temperature -25~+70
Elevation m ≤2000
Pollution degree
Terminal connection type Cable/Pin-type busbar
Installation Environment No obvious vibration and shock
Installation category
Mounting On DIN rail EN60715(35mm)by means of fast clip