YCB7RL-100 Electromagnetic RCCB

0 Reviews Sold: 0

YCB7RL-100 series electromagnetic residual current operated circuit breaker is mainlysuitable for AC distribution networks with a rated working voltage of 230V or 400V at 50Hzand a rated current of 63A.Used for indirect contact protection of people,and can also beused to prevent fire hazards caused by insulation damage to circuits and equipment,resulting in ground fault currents.

Product Details

 

General

YCB7RL-100  series  electromagnetic  residual  current  operated  circuit  breaker  is  mainly suitable for AC distribution networks with a rated working voltage of 230V or 400V at 50Hz  and a rated current of 63A.Used for indirect contact protection of people,and can also be used  to  prevent  fire   hazards  caused   by  insulation  damage  to  circuits  and  equipment,  resulting in ground fault currents.

Feature

Protection against the effects of sinusoidal alternating earth fault currents.The leakage protection feature does not require an auxiliary power supply.Not affected by voltage fluctuations in the power grid.

Selection

YCB7RL 100 1P+N 63 100mA A Type
Mode Shell grade
current
Pole Rated current Rated  residua
operating current
Type
RCCB
Electromagnetic
100 1P+N
3P+N
6
10
16
20
25
32
40
50
63
Default:
30mA
100mA
300mA
Default:AC Type       A Type

 

Technical data

Model   YCB7RL-100
Electrical
features
Leakage type Electromagnetic type
Rated current In A 6,10,16,25,32,40,50,63,80,100
Type (wave form of the earth leakage sensed) A,AC
Poles P 1P+N,3P+N
Rated voltage Ue V 230/400
Insulation voltage Ui V 500
Rated frequency Hz 50/60
Rated breaking capacity Inc=I△c A 600,010,000
Rated impulse withstand voltage (1.2/50)Uimp V 6000
Dielectric test voltage at ind.Freq.for 1min Kv 2.5
Rated sensitivity I△n A 0.03,0.1,0.3
Rated residual making and breaking capacity lAm A 500(In≤40A);630(In=50A/63A);1000(In=80A/100A
Pollution degree 2
Electrical life t 4000
Mechanical
features
Mechanical life t 8000
Protection degree IP20
Storage temperature -25~+70
Ambient temperature (with daily average≤35℃) -5~+40
Terminal connection type Cable/Pin-type busbar/U-type busbar
Installation Terminal size top /bottom for cable mm² 25/35
Terminal size top /bottom for busbar AWG 18-3/18-2
Tightening torque mm² 10/16
AWG 18-8/18-5
Mounting N*m 2.5
In-Ibs 22
Connection On DIN rail EN 60715(35mm)by means of fast clip device
From top or bottom

color

,

Reviews

There are no reviews yet.

Be the first to review “YCB7RL-100 Electromagnetic RCCB”